
Presented By: Taylor Towler August 2025 – Confidential
2

20+ years of Tier III/IV data center delivery expertise.
Pioneering liquid-cooling and gas-to-DC methods since 2018.
Implementing DoD-grade cyber/GRC standards for ultimate protection.
Utilizing patented AI training optimization techniques.
Expertise in hyperscale Managed Service Provider (MSP) execution.
Track record of successful EPC negotiations exceeding $1B.
3

Modular, liquid-cooled, high-density halls and colocated generation designed for maximum efficiency and scalability.
Comprehensive oversight from BOD through commissioning and handover, ensuring adherence to specifications and timeline.
Structured capital paths with strategic incentives packaging to optimize investment and maximize returns.
Carrier-grade routes, dark-fiber option, multi-Tb/s fabrics designed for optimal connectivity and performance.
4

≤ 9 months from site acquisition to Ready For Service.
PUE ≤ 1.20 (annualized) and WUE ≤ 25th-percentile, with real-time monitoring.
SOC 1/2/3, ISO 27001, and Uptime Tier III baseline, with a-la-carte HIPAA, PCI DSS, NIST, CMMC, and DoD IL4-5.
140–300kW/rack Day-1, with an engineered path to 1 MW/rack and minimal re-work.
Featuring rapid grid sites, gas + BESS, and options for SMR-ready or own-the-well gas origination.
5

At Solomon Data Systems, our foundational principles guide every decision and action. These values are the bedrock of our commitment to excellence and client success in delivering future-proof infrastructure.
6

140–300kW/rack initial → 1 MW/rack with modular upgrades; ΔT and dew-point controls verified in IST.
Open-protocol BMS, continuous-commissioning analytics, pre-IST simulation for optimized performance.
7

Transformers and other LLE at ≤ 4 months from IFC, significantly faster than industry standard.
Prefab wires/busway/power skids concurrent with dried tilt-up in 18 weeks; multi-shift execution. Nominal construction 6–8 months.
≤ 6 weeks IST window, Level 4–5 Cx with failure scenarios, digital-twin pre-validation ensuring rapid deployment.
8

20 minutes (client options beyond 20 min justified by NPV)
Natural-gas preferred, replacing diesel to hedge grid outage trends; diesel available on request or as a holdover until gas arrival
UPS peak-shave/ACCS to cap campus ramp and reduce peaks
9

Designs support ≥ 800 Gbps to multi-Tb/s fabrics; interoperability under RFC 2544 stress testing.
10

Biometric 2FA; Drone Surveillance; Self Healing OT; 24/7 Human Personnel
US-origin controls only; no offshore controls.
11


12

13

SDS is engaged on a U.S. hyperscale campus opportunity with up to 5 GW gas + 1 GW solar. SDS roles are deal structuring & go-to-market; gas supply/dispatch analysis; convening IPPs; PPA design & financial modeling; interface to hyperscalers and capital providers.
Feasibility & business-case program. Tier I 10-day recon; Tier II 6-week bankable study with 8760 10-year pro-formas.
End-to-end data center execution management; BOD Management; Compliance; Financing Support; Existing-Tenant Deal Structuring; Lease Document Creation; Lease-Up Support; Final Design; Owner's Rep; EPC Project Management; Networking; Commissioning; Staffing; SOP Creation; Security; Insurance; Natural Gas N+1.
Tenant/finance de-risking; generation-strategy diligence; lease-up; PM; represent site owner to leading AI hyperscaler. (Proposal under client evaluation.)
Relocating ≈180 liquid-cooled racks (110 kW each) from EU to U.S.; SDS managing Q4 SLA start.
Invited to PNNL's DC Industry Advisory Board—Enhanced Geothermal Systems leveraging liquid-cooled waste heat.
14


Built and scaled compute businesses at speed; exclusive rep on 250 MW+ site sales; delivered 31 MW in 6 months, including 5 MW in 13 weeks; scaled Merov from $0→$38M in 9 months, educator.

25+ yrs in sourcing/contracts & SRM; led META MSP procurement (S2C/P2P, OFCI). Stabilized a ~$1B cogeneration project; delivered complex renewable PPA evaluations.

20-year senior leader building security/ops platforms across cleared and commercial programs; head of network analysis in national security role for 8 years.

20-year innovator across data centers, energy, and AI; 2 patents; architect of the "Shader Method" (BESS-as-UPS).

Seasoned operator and sales leader with a track record of building, scaling, and exiting ventures; developed international partnerships across data center infrastructure and AI.
Paul Vaccaro — 30+ yrs in mission critical; $1B+ Tier III/IV data center projects; design/construction/operations.
Erik Nilsen, PhD — polymath technologist; $600M+ grants won, $1.7B+ advised investments; 7+ patents.
Fede Lang — 20-year DC executive; hyperscale deployments & partnerships.
15

140–300 kW/rack Day-1 with an engineered path to 1 MW/rack.
PUE ≤ 1.20 (annualized), placing our facilities in the top tier of data center efficiency and significantly reducing operating costs.
≤ 9 months from site-acquisition to RFS, with integrated power strategy ensuring you're operational faster than traditional approaches.
One accountable delivery chain from design through operations, eliminating the complexity of managing multiple vendors and contracts.
16

We look forward to discussing how Solomon Data Systems can deliver value for your organization.
17


Address: 5900 Balcones Drive #25361
Austin, TX, 78731
Phone: (262) 365-9132
Email: taylor@solomondatasystems.com
Website: www.solomondatasystems.com
18

PUE ≤ 1.20 (annualized); WUE ≤ 25th-percentile (annualized); metering per ISO/IEC 30134-2; site-specific M&V post-award.
SOC 1/2/3, ISO 27001, Uptime Tier III baseline; control evidence managed in Secureframe; independent audits/attestations by Schellman.
24×7 operations & facilities management; NOC/remote-hands coverage, shift rosters, and SOP/MOP/LOTO readiness; managed by senior internal staff.
Standardize natural-gas gensets to hedge Texas SB6 and similar trends nationally—delivering uptime fuel assurance, lower emissions/noise, and faster permitting.
19

DTC 110/135°F ASHRAE W4/W5; dual-loop hydraulics; trim coils; ΔT and dewpoint controls; maintain rack inlet ≤ 90°F at 100% load.
140–300 kW/rack Day-1; engineered path to 1 MW.
Distributed-redundant power topology; PUE metering per ISO/IEC 30134-2; BESS 20 min.
Open-protocol BMS; continuous-commissioning analytics; digital-twin pre-IST; sensor polling ≤ 5 s.
Biometric two-factor mantraps; AI video analytics; US-origin controls only; SBOM/firmware audit.
Transformers ~4 mo; prefab concurrent; dried tilt-up 18 wks; 6–8 mo construction; ≤6 wk IST.
20

Solomon Data Systems